headerblueheaderblueheaderblue
ppeFlash
Power Plant Equipment PhotoPower Plant Equipment Photo Power Plant Equipment PhotoPower Plant Equipment Photo Power Plant Equipment Photo
 
Address
top

topfeature

Request for deaerator quote

Fill out the form below, and we will get back in touch with you ASAP.

 

Requested by:
 
Project Information: *fill out as much info as available
This Deaerator Project is influenced primarily by:  
Project Name:
Date Quote Requested by:
#/hour
PSIG
%  - °F
%  - °F
%  - °F
*Note:  Makeup water % + High Temp. Return % + Low Temp. Return % must equal 100% (Capacity of deaerator)
Deaerator Type:

Deaerator Components

 

  1. Vessel
  2. Support Stand
  3. Control Panel
  4. Pumps
  5. Steam Pressure Control
  6. Water Level Control
  7. Special Feature Equipment
Vessel

Standard Features Include:

  • ASME Design 50 PSIG—operating pressure 5 PSIG
  • 12” x 16” manway
  • Vessel mounted stainless steel temperature gauge with thermal well
  • Safety type heavy duty red lined level gauge with isolation valves
  • Low temperature pump condensate return connection
  • Vessel mounted sentinel warning valve (will require full capacity relief valve in customer steam piping)
  • Vessel mounted 4” stainless steel pressure gauge
  • 6 minute storage capacity
  • Prime and finish paint
 

Optional Features:

 

Stainless steel chemical injection quill
Full capacity relief valve mounted on the vessel (in lieu of sentinel warning valve).
High temperature condensate return connection

10 min storage capacity

Full capacity relief valve shipped loose for mounting on customer's steam line.

Magnesium anode for corrosion protection.

Other requirements:
   

 

Support Stand

Standard Features Include:

  • Designed for dead load and minor seismic activity
  • Stand height based upon required pump NPSH
  • Control panel mounted on stand

  • Prime and finish paint
 

Optional Features:

 

Remote pressure/temperature gauges

Design for specific seismic activity.
  List seismic zone:
Other requirements:
   

 

 

Control Panel

Standard Features Include:

  • NEMA 1 control panel
  • MAG starters with HOA switches and run-lights
  • High level, low level and low—low pump cutoff with alarm horn and push to silence button
 

Optional Features:

 

NEMA 4
NEMA 12

 
Panel mounted main disconnect
If Other, specify
   

 

 

Pumps
Number of Pumps
GPM flow per pump
PSIG Discharge Pressure
Pref. Manuf. and model #
Motor Type ODP  OR  TEFC
Voltage & Phase
 
Pumps Suction Line

Standard Features Include:

  • Pump Discharge Header- with isolation valve, check valve and discharge pressure gauge.

  • Each pump supplied with an individual suction line connection sized at least one pipe sizes larger than pump suction.

  • Each suction line includes isolation valve, flexible connector and Y-strainer with strainer blowdown valve.
  • Individual pump isolation valve
  • Indvidual check valve
 

Optional Features:

 

*if items below are checked, then Discharge header is required.
With glycerin filled SS pressure gauges
With individual recirculation line
 
Other Requirements:
   

 

Steam Pressure Control

Standard Features Include:

  • Pilot operated self contained steam PRV with valve shipped loose for mounting in customer piping
 

Optional Panel Features:

 

3 valve bypass assembly

  * 3-valve bypass, if required, is shipped loose for mounting in customer piping (includes two line sized isolation valves and reduced size bypass globe valves).
 
Other Requirements:
   

 

Water Level Controls
Level Control (Select One)


Mechanical—float type with mechanical linkage to control valve (Least expensive)

Pneumatic—displacer float type to pneumatic control valve

Electric—float type with modulating signal output to motorized control valve
Differential pressure transmitter with panel mounted PLC to electric modulating control valve
Other
  If Other selected, please describe:
 
Optional Level Control Features:
3 valve bypass (includes two line sized isolation valves and reduced size bypass globe valves).
  Other Requirements:

 

Other Special Features and Equipment
Describe other required equipment features and options not addressed above:

 